Amyvid Injection

Name: Amyvid Injection

Indications and Usage for Amyvid Injection

Amyvid is indicated for Positron Emission Tomography (PET) imaging of the brain to estimate β-amyloid neuritic plaque density in adult patients with cognitive impairment who are being evaluated for Alzheimer's Disease (AD) and other causes of cognitive decline. A negative Amyvid scan indicates sparse to no neuritic plaques and is inconsistent with a neuropathological diagnosis of AD at the time of image acquisition; a negative scan result reduces the likelihood that a patient's cognitive impairment is due to AD. A positive Amyvid scan indicates moderate to frequent amyloid neuritic plaques; neuropathological examination has shown this amount of amyloid neuritic plaque is present in patients with AD, but may also be present in patients with other types of neurologic conditions as well as older people with normal cognition. Amyvid is an adjunct to other diagnostic evaluations.

Limitations of Use:

  • A positive Amyvid scan does not establish a diagnosis of AD or other cognitive disorder.
  • Safety and effectiveness of Amyvid have not been established for:
    • Predicting development of dementia or other neurologic condition;
    • Monitoring responses to therapies.

Amyvid Injection Dosage and Administration

Radiation Safety - Drug Handling

Amyvid is a radioactive drug and should be handled with appropriate safety measures to minimize radiation exposure during administration [see Warnings and Precautions (5.1)]. Use waterproof gloves and effective shielding, including syringe shields when handling Amyvid. Radiopharmaceuticals, including Amyvid, should only be used by or under the control of physicians who are qualified by specific training and experience in the safe use and handling of radioactive materials, and whose experience and training have been approved by the appropriate governmental agency authorized to license the use of radiopharmaceuticals.

Recommended Dosing and Administration Instructions

The recommended dose for Amyvid is 370 MBq (10 mCi), maximum 50 μg mass dose, administered as a single intravenous bolus in a total volume of 10 mL or less. Follow the injection with an intravenous flush of 0.9% sterile sodium chloride.

  • Inspect the radiopharmaceutical dose solution prior to administration and do not use it if it contains particulate matter or is discolored.
  • Use aseptic technique and radiation shielding to withdraw Amyvid solution.
  • Assay the dose in a suitable dose calibrator prior to administration.
  • Inject Amyvid through a short intravenous catheter (approximately 1.5 inches or less) to minimize the potential for adsorption of the drug to the catheter. Portions of the Amyvid dose may adhere to longer catheters.

Image Acquisition Guidelines

A 10-minute PET image should be acquired starting 30 to 50 minutes after Amyvid intravenous injection. The patient should be supine and the head positioned to center the brain, including the cerebellum, in the PET scanner field of view. Reducing head movement with tape or other flexible head restraints may be employed. Image reconstruction should include attenuation correction with resulting transaxial pixel sizes between 2 and 3 mm.

Image Display and Interpretation

Amyvid images should be interpreted only by readers who successfully complete a special training program [see Warnings and Precautions (5.1)]. Training is provided by the manufacturer using either an in-person tutorial or an electronic process.

The objective of Amyvid image interpretation is to provide an estimate of the brain β-amyloid neuritic plaque density, not to make a clinical diagnosis. Image interpretation is performed independently of a patient's clinical features and relies upon the recognition of unique image features.

Image Display

Images should be displayed in the transaxial orientation with access as needed to the sagittal and coronal planes. In reviewing the images, include all transaxial slices of the brain using a black-white scale with the maximum intensity of the scale set to the maximum intensity of all the brain pixels. Initially locate the brain slice with the highest levels of image contrast (highest radioactivity signals for Amyvid uptake) and adjust the contrast appropriately. Start image interpretation by displaying slices sequentially from the bottom of the brain to the top. Periodically refer to the sagittal and coronal plane image display, as needed to better define the radioactivity uptake and to ensure that the entire brain is displayed.

Image Interpretation

Image interpretation is based upon the distribution of radioactive signal within the brain; clinical information is not a component of the image assessment [see Warnings and Precautions (5.1)]. Images are designated as positive or negative by comparing the radioactivity in cortical gray matter with activity in the adjacent white matter. This determination is made only in the cerebral cortex; the signal uptake in the cerebellum does not contribute to the scan interpretation (for example, a positive scan may show retained cerebellar gray-white contrast even when the cortical gray-white contrast is lost).

  • Negative scans show more radioactivity in white matter than in gray matter, creating clear gray-white contrast.
  • Positive scans show cortical areas with reduction or loss of the normally distinct gray-white contrast. These scans have one or more areas with increased cortical gray matter signal which results in reduced (or absent) gray-white contrast. Specifically, a positive scan will have either:
    1. Two or more brain areas (each larger than a single cortical gyrus) in which there is reduced or absent gray-white contrast. This is the most common appearance of a positive scan.

      or

    2. One or more areas in which gray matter radioactivity is intense and clearly exceeds radioactivity in adjacent white matter.

Some scans may be difficult to interpret due to image noise, atrophy with a thinned cortical ribbon, or image blur. For cases in which there is uncertainty as to the location or edge of gray matter on the PET scan and a co-registered computerized tomography (CT) image is available (as when the study is done on a PET/CT scanner) the interpreter should examine the CT image to clarify the relationship of the PET radioactivity and the gray matter anatomy.

Figures 1, 2, and 3 provide examples of negative and positive scans. Figure 1 demonstrates varying degrees of normal gray-white contrast (negative) and examples where gray-white contrast has been lost (positive). Figure 2 illustrates typical features of a negative scan, while Figure 3 shows the loss of gray-white contrast in different brain regions of a positive scan.

Figure 1: Examples of Amyvid negative scans (top two rows) and positive scans (bottom two rows). Left to right panels show sagittal, coronal, and transverse PET image slices. Final panel to right shows enlarged picture of the brain area under the box. The top two arrows are pointing to normal preserved gray-white contrast with the cortical radioactivity less than the adjacent white matter. The bottom two arrows indicate areas of decreased gray-white contrast with increased cortical radioactivity that is comparable to the radioactivity in the adjacent white matter.

Figure 2: Typical Negative Scan. Images are displayed from a negative scan with upper (top) and lower (bottom) transverse slices both showing good gray-white matter contrast. On the right side of each slice, dotted lines have been used to illustrate the edge of the cortical gray matter (outer line) and the gray-white border (inner line). These dotted lines highlight contrast in uptake between the less intense uptake in the gray matter and the more intense uptake in the white matter. In addition, arrows illustrate the following points:
A) White matter tracts can be delineated from the frontal lobe to parietal lobe.
B) White matter tracts are clearly identified throughout the occipital / temporal area.
C) Scalloped appearance is seen with “fingers” of white matter in the frontal cortex.
D) Low levels of tracer in scalp or skull that should be distinguished from gray matter uptake by its shape and position.

Figure 3: Typical Positive Scan: Images from a positive scan showing upper (top) and lower (bottom) transverse slices with loss of gray-white matter contrast in multiple brain regions. On the right side of each slice the edge of the cortical gray matter has been illustrated with a dotted line. Compared to the images from the negative case in Figure 2, the gray matter uptake is more similar to the white matter uptake and the gray-white matter border is more difficult to discern. In addition, arrows show the following points:
A) White matter tracts are difficult to fully identify as they travel from frontal to parietal lobe.
B) Borders of white matter tracts in occipital / temporal area are lost in places.
C) Gray matter in medial parietal cortex (precuneus) has increased uptake.
D) Low levels of tracer in scalp or skull that should be distinguished from gray matter uptake by its shape and position.

Radiation Dosimetry

The estimated radiation absorbed doses for adults from intravenous injection of Amyvid are shown in Table 1.

Table 1: Estimated Radiation Absorbed Dose, Amyvid (Florbetapir F 18 Injection)

a Gastrointestinal

b Assumed radiation weighting factor, wr, (formerly defined as quality factor, Q) of 1 for conversion of absorbed dose (Gray or rads) to dose equivalent (Sieverts or rem) for F 18. To obtain radiation absorbed dose in rad/mCi from above table, multiply the dose in μGy/MBq by 0.0037, (e.g., 14 μGy/MBq x 0.0037 = 0.0518 rad/mCi)

ORGAN/TISSUE MEAN ABSORBED DOSE PER UNIT
ADMINISTERED ACTIVITY(μGy/MBq)
Adrenal 14
Bone - Osteogenic Cells 28
Bone - Red Marrow 14
Brain 10
Breasts 6
Gallbladder Wall 143
GIa - Lower Large Intestine Wall 28
GI - Small Intestine 66
GI - Stomach Wall 12
GI - Upper Large Intestine Wall 74
Heart Wall 13
Kidneys 14
Liver 64
Lungs 9
Muscle 9
Ovaries 18
Pancreas 14
Skin 6
Spleen 9
Testes 7
Thymus 7
Thyroid 7
Urinary Bladder Wall 27
Uterus 16
Total Body 12
Effective Dose (μSv/MBq)b 19

The effective dose resulting from a 370 MBq (10 mCi) dose of Amyvid is 7.0 mSv in an adult, (19 x 370 = 7030 μSv = 7.030 mSv). The use of a CT scan to calculate attenuation correction for reconstruction of Amyvid images (as done in PET/CT imaging) will add radiation exposure. Diagnostic head CT scans using helical scanners administer an average of 2.2 ± 1.3 mSv effective dose (CRCPD Publication E-07-2, 2007). The actual radiation dose is operator and scanner dependent. The total radiation exposure from Amyvid administration and subsequent scan on a PET/CT scanner is estimated to be 9 mSv.

Dosage Forms and Strengths

Amyvid (Florbetapir F 18 Injection) is available in a 10 mL, 30 mL, and 50 mL multidose vial containing a clear, colorless solution at a strength of 500-1900 MBq/mL (13.5-51 mCi/mL) florbetapir F 18 at End of Synthesis (EOS).

Drug Interactions

Pharmacodynamic drug-drug interaction studies have not been performed in patients to establish the extent, if any, to which concomitant medications may alter Amyvid image results.

Within a clinical study of patients with a range of cognitive impairment, some patients with probable AD were receiving the following medications: donepezil, galantamine, memantine. Mean cortical Standardized Uptake Value (SUV) ratios did not differ between the patients taking or not taking these concomitant medications. In in vitro tests, none of the drugs tested, including the acetylcholinesterase inhibitors donepezil, galantamine, and tacrine, altered florbetapir F 18 binding to its target.

Amyvid Injection - Clinical Pharmacology

Mechanism of Action

Florbetapir F 18 binds to β-amyloid plaques and the F 18 isotope produces a positron signal that is detected by a PET scanner. In in vitro binding studies using postmortem human brain homogenates containing β-amyloid plaques, the dissociation constant (Kd) for florbetapir was 3.7 ± 0.3 nM. The binding of florbetapir F 18 to β-amyloid aggregates was demonstrated in postmortem human brain sections using autoradiographic methods, thioflavin S and traditional silver staining correlation studies as well as monoclonal antibody β-amyloid-specific correlation studies. Florbetapir binding to tau protein and a battery of neuroreceptors was not detected in in vitro studies.

Pharmacodynamics

Following intravenous injection, florbetapir F 18 diffuses across the human blood-brain barrier and produces a radioactivity signal detectable throughout the brain. Subsequently, cerebral perfusion decreases the brain florbetapir F 18 content, with differential retention of the drug in areas that contain β-amyloid aggregates compared to areas that lack the aggregates. The time-activity curves for florbetapir F 18 in the brain of subjects with positive scans show continual signal increases from time zero through 30 minutes post-administration, with stable values thereafter up to at least 90 minutes post-injection. Differences in the signal intensity between portions of the brain that specifically retain florbetapir F 18 and the portions of the brain with nonspecific retention of the drug forms the image interpretation methods [see Dosage and Administration (2.4)].

Clinical studies evaluated the test-retest distribution of florbetapir F 18 within the brains of 21 subjects (11 with probable AD and 10 healthy volunteers) who underwent two injections (with PET scans), separated by a time period of 2 to 30 days. Images were shown to maintain signal distribution reproducibility when evaluated qualitatively (by a reader masked to image time points) as well as quantitatively using an automated assessment of SUV in pre-specified brain regions. A comparison of a 10-minute image acquisition time versus a 20-minute acquisition time showed no difference in the mean cortical to cerebellar SUV ratio results obtained.

Pharmacokinetics

Following the intravenous administration of 370 MBq (10 mCi) of florbetapir F 18 to healthy volunteers, the drug was distributed throughout the body with less than 5% of the injected F 18 radioactivity present in the blood by 20 minutes following administration, and less than 2% present by 45 minutes after administration. The residual F 18 in circulation during the 30-90 minute imaging window was principally in the form of polar F 18 metabolites. Whole body scanning following the intravenous injection showed accumulation of radioactivity in the liver within four minutes post-injection, followed by elimination of the radioactivity predominantly through the biliary/gastrointestinal tract with much lower radioactivity detected in the bladder. Essentially all radioactivity collected in the urine was present as polar metabolites of florbetapir F 18.

Clinical Studies

Amyvid was evaluated in three clinical studies that examined images from healthy adult subjects as well as subjects with a range of cognitive disorders, including some terminally ill patients who had agreed to participate in a postmortem brain donation program. All the studies were single arm studies in which subjects underwent an Amyvid Injection and scan and then had images interpreted by multiple independent readers who were masked to all clinical information. Image interpretations used co-registration with CT scans when PET scans were performed on dual PET-CT scanners.

In Study One, a semi-quantitative Amyvid image interpretation method, which is not intended for clinical use, was used by three readers to interpret images from 152 terminally ill patients, of whom 35 underwent autopsy (29 included in primary analysis). The median patient age was 85 years (range 55 to 103 years) and 14 of the patients were female. Eighteen of the patients had dementia, 9 had no cognitive impairment and 2 had mild cognitive impairment (MCI). The main study outcome was a comparison of premortem Amyvid images to the findings from a postmortem brain examination (truth standard). The semi-quantitative measures consisted of a five-point whole brain Amyvid uptake image scoring outcome that was compared to a global score of the percentage of the whole brain that contained amyloid, as determined by immunohistochemical microscopy. The percentage of postmortem cortical amyloid burden ranged from 0 to 9% and correlated with the median Amyvid scores (Spearman's rho=0.78; p<0.0001, 95% CI, 0.58 to 0.89).

Studies Two and Three used a clinically-applicable binary image interpretation method (positive/negative) to evaluate images from a range of patients who had participated in earlier studies. The studies assessed performance characteristics (sensitivity and specificity) among subjects with a postmortem amyloid neuritic plaque density truth standard. Additionally, inter-reader and intra-reader image interpretation reproducibility was assessed among all the subjects, including subjects who lacked a postmortem truth standard. Before image interpretation, all readers underwent special training: Study Two used an in-person tutoring type of training and Study Three used an electronic media-based training method. Five trained readers interpreted images independently within each study. The brain neuritic plaque density in both studies was determined using an algorithm in which microscopic measures of highest plaque density within a brain region were averaged to produce a global brain estimate of neuritic plaque density. The global neuritic plaque density was categorized in the same manner as that for a region (Table 5), where plaques were counted on slides with modified Bielschowsky silver stained tissue sections. For purposes of determining the agreement between the in-vivo Amyvid image results and the post-mortem whole brain amyloid neuritic plaque density, Amyvid results (negative/positive) were pre-specified to correspond with specific plaque density scores, based upon a modification of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) criteria which use neuritic plaque counts as a necessary pathological feature of AD.

Table 5: Global and Regional Neuritic Plaque Densitya Correlates to Amyvid Image Results

a J of Neuropathology and Experimental Neurology 1997; 56(10):1095.

Neuritic Plaque Counts CERAD Score Amyvid Image Result
<1 none Negative
1 - 5 sparse
6 - 19 moderate Positive
20+ frequent

Study Two examined images only from terminally ill patients who had premortem Amyvid scans and postmortem brain examinations to determine a truth standard. Among the 59 patients, 35 of whom were also in Study One, the median age was 83 years (range 47 to 103 years), half were females and most were Caucasian (93%). Twenty-nine patients had an AD clinical diagnosis, 13 had another type of dementing disorder, 12 had no history of cognitive impairment and 5 had MCI. The time interval between the Amyvid scan and death was less than one year for 46 patients and between one and two years for 13 patients. Among the subset of patients who died within one year of Amyvid scanning (a prespecified outcome), the sensitivity using the majority interpretation of the readers was 96% (95% CI: 80% to 100%) and specificity was 100% (95% CI: 78% to 100%). With the entire dataset of 59 patients, the sensitivity using the majority interpretation of the readers was 92% (95% CI: 78% to 98%) and specificity was 100% (95% CI: 80% to 100%). At autopsy, the global brain neuritic plaque density category (CERAD score, as in Table 5) was: frequent n=30; moderate n=9; sparse n=5; and none n=15. Tables 6 and 7 show the Amyvid performance characteristics among all the patients. Among the subset of patients who died within one year of Amyvid scanning (n=46; 28 positive and 18 negative based on histopathology) the median (and range) of correct read results, false negatives, and false positives were 44 (37 to 45), 1 (0 to 7), and 1 (0 to 2), respectively, for In-Person Training (Study Two); and were 43 (38 to 44), 3 (0 to 7), and 1 (0 to 2), respectively, for Electronic Media Training (Study Three).

Table 6: Amyvid Scan Results by Reader Training Method among Autopsied Patients (n = 59)
Test Performance In-Person Training
(Study Two)
Electronic Media Training
(Study Three)
Sensitivity (%) Median 92 82
Range among the 5 readers (69 – 95) (69 – 92)
Specificity (%) Median 95 95
Range among the 5 readers (90 – 100) (90 – 95)
Table 7: Amyvid Correct and Erroneous Scan Results by Reader Training Method among Autopsied Patients

a 39 positive and 20 negative based on histopathology

Read Result In-Person Training
(Study Two)
Electronic Media Training
(Study Three)
Reader Reader
1 2 3 4 5 6 7 8 9 10
All Scans with Autopsies (N=59a) Correct 55 56 53 56 45 49 54 46 53 51
False Negative 3 2 5 3 12 8 3 12 5 7
False Positive 1 1 1 0 2 2 2 1 1 1

Study Three included images from subjects who did not have a truth standard (20 healthy volunteers, 52 patients with mild cognitive impairment, 20 patients with AD) as well as all 59 of the patients who underwent an autopsy (same patients as in Study Two) and provided a truth standard. Duplicate images of 33 patients were included within the total pool of images in order to assess intra-reader image reproducibility. Among the 151 subjects, the median age was 76 years (range 47 to 103), half were females and most were Caucasian (93.4%). Performance characteristics for patients with a truth standard are shown above (Tables 6 and 7). The major reproducibility results are shown in Table 8 for various groups of subjects. Inter-reader reproducibility analyses for all images showed an overall Fleiss' kappa statistic of 0.83 (95% CI: 0.78 to 0.88); the lower bound of the 95% CI exceeded the pre-specified success criterion (95% CI lower bound >0.58). Intra-reader reproducibility analyses showed that, between the two readings for each of the 33 patients with duplicate images, one of the five readers had complete agreement for all 33 patients, two readers had discrepant reads for a single patient, one reader had discrepant reads for two patients and another reader had discrepant reads for three patients.

Table 8: Number of Positive Amyvid Scan Results within Study Three Subject Groups and Reproducibility of Scan Results Among Readers

a Shown is the median number of scans interpreted as positive across the 5 readers for each subgroup of patients listed in the first column.

Subject group
by cognitive and truth standard
(TS, autopsy) status
Positive Scans, na Kappa
(95% CI)
Percent of Scans with Inter-reader Agreement
3 of 5 readers agree 4 of 5 readers agree 5 of 5 readers agree
All subjects with a TS, n=59 33 0.75
(0.67, 0.83)
14 10 76
All subjects without a TS, n=92 33 0.88
(0.82, 0.94)
2 11 87
AD, n=49
(29 with TS; 20 no TS)
38 0.67
(0.58, 0.76)
10 14 76
MCI, n=57
(5 with TS; 52 no TS)
17 0.91
(0.83, 0.99)
2 7 91
Cognitively normal without TS, n=20 4 0.83
(0.69, 0.97)
5 5 90
Cognitively normal with TS, n=12 1 0.73
(0.55, 0.87)
0 8 92
Other (non-AD) dementia with TS, n=13 7 0.52
(0.35, 0.69)
23 23 54
(web3)